| Model No | Power/W | Light Size | Waterproof | TA | LED Type |
| KA06-13 | 25W | 488*185*101 | IP65 | -30℃-+50℃ | SMD |
| 50W | IP65 | ||||
| KA06-15 | 50W | 577*232.6*103.2 | IP65 | ||
| 60W | IP65 | ||||
| KA06-110 | 80W | 627*271.5*103.2 | IP65 | ||
| 100W | IP65 | ||||
| 120W | IP65 | ||||
| KA06-115 | 120W | 768*301*103.5 | IP65 | ||
| 150W | IP65 | ||||
| 180W | IP65 | ||||
| 200W | IP65 | ||||
| 240W | IP65 |

1. IP65 waterproof and dustproof effect 2. Adjustable angle. After removing the lamp handle,rotate the angle of the lamp handle once to obtain a brand-new 90°product style. 3. High quality shell with hight technology 4. The lamp beads are evenly distributed and beautiful The perfect combination of the lamp beads and the black glass shell makes the original ordinary lamp immediately become advanced.



Application site: City road / tunnel lighting Commercial lighting control Solar street smart lighting control Features: Lamp on/off/Dim/metering/alarm operation/strategy storage Loop control optional (1~8 loops) Advantage: Easy to install Strong system expansion ability and increase sensor devices Low power consumption, large capacity, high stability
Application site: City road /tunnel lighting Commercial lighting control Smart Park Frequency Band Optional: 433/470/EU868/US915/AS923/AU923MHz Features: Lamp on/off/Dim/metering/alarm operation/strategy storage LoRa gateway coverage radius of 2-5kilometer Advantage: Easy to install Strong system expansion ability and increase sensor devices Low power consumption, large capacity , high stability
Application site: City road / tunnel lighting Commercial lighting control Solar street smart lighting control Features: Lamp on/off/Dim/metering/alarm operation/strategy storage Advantage: Easy to install Strong system expansion ability and increase sensor devices Low power consumption, large capacity , high stabilityMatters needing attention • Before installing the lighting fixtures, please read this instruction manual carefully. • The lighting fixtures should be installed, connected and tested by a certified electrician based on the local regulations. • Lamps should always be installed or replaced carefully. • Please check the local voltage in accordance with the product requirements before installation. • Revamping only can be done when the power is off and the lamp is completely cooled down. • When clean the lamp, make the power off and let it cool down completely, clean the fixture with a soft cloth and a standard PH neutral detergent, stainless steel should be maintained regularly. • Don’t cover the fixtures with flammable materials. • Replace should be made by the manufacturer or his service agent or certified electrician in order to avoid a hazard. Temperature Characteristics T-ambient 25℃ Temperature Operating -20~+55℃ Storage -40~+60℃ Electrical Characteristics Input Voltage: AC100-277V 50/60Hz PF:>0.9 Power Efficiency:≧0.90Features • IP66 waterproof/dust proof/explosion proof/IK09 • Aluminum shape good at heat dissipation • The lamp post can be adjusted to plus or minus 15 degrees It can also be installed vertically • Philips SMD 3030/ 5050/ Ra>70/SDCM<6 • 100,000 times switching cycle before failure • Total harmonic distortion(THD)<10% • Excellent post light control design, the whole lamp can achieve T II-M, T III-M,That's our advantage • Pass 3G vibration testApplication ROAD LIGHTING It is mainly applied to the road lighting of urban expressway,secondary trunk road, branch road, factory, school, garden, various residential communities and courtyards. The installation height is 6-13m and the installation torque is 16Nm.Product Dimension
| Model NO. | Size L(mm) | Size W(mm) | Size H(mm) | Support pole diameter |
| R06-13 | 487.4 | 185 | 101 | 50/60 |
| R06-15 | 577 | 232.5 | 103 | 60 |
| R06-110 | 627 | 271.5 | 103 | 60 |
| R06-115 | 768 | 301 | 103.5 | 60 |
| Model NO. | Power(W) | Light Source | LED QTY (PCS) | Lens(PCS) | CCT(K) | Lumen(lm/W) | CRI |
| R06-13-30W | 30 | 3030(5050) | 48/24 | 4 | 4000k | 130/150 | >70 |
| R06-13-40W | 40 | 3030(5050) | 64/32 | 4 | 4000k | 130/150 | >70 |
| R06-15-50W | 50 | 3030(5050) | 96/36 | 6 | 4000k | 130/150 | >70 |
| R06-15-60W | 60 | 3030(5050) | 96/48 | 6 | 4000k | 130/150 | >70 |
| R06-110-80W | 80 | 3030(5050) | 144/54 | 9 | 4000k | 130/150 | >70 |
| R06-110-100W | 100 | 3030(5050) | 144/54 | 9 | 4000k | 130/150 | >70 |
| R06-110-120W | 120 | 3030(5050) | 144/72 | 9 | 4000k | 130/150 | >70 |
| R06-115-150W | 150 | 3030(5050) | 192/96 | 16 | 4000k | 130/150 | >70 |
| R06-115-180W | 180 | 3030(5050) | 256/96 | 16 | 4000k | 130/150 | >70 |
| R06-115-200W | 200 | 3030(5050) | 320/120 | 20 | 4000k | 130/150 | >70 |
| Item | Symbol | specification/Data |
| Color Index | CRI | Ra>70,R9>0 |
| Luminous Efficacy | lm/W | 130--160 lm/W |
| Energy efficiency Class | / | A++ |
| Color consistency in level | / | Max.6SDCM |
| THD | / | <15% |
| Starting Time | S | <0.5S |
| Switching cycle before failure | / | >100,000times |
| Premature failure rate@1000h | / | 0 |
| Lifespan | H | >50000Hrs |
Installation way
• Installing steps Turn off the power before installing Make sure the model, rated voltage and wattage are the same with the design parameters Check the wire specification , Connect the wire,Through the waterproof connector, connect the L/N wire of the street lamp to L/N wire of the city electricity. 1. Put the light into the light stem ( picture 1) 2. Fix the screw of handle ( picture 2) 3. Check the installing of the light whether level or not. 4.Adjust the angle into which needed ( picture 3). 5. Check the the handle screw fixed or not, if loose, should make it tightly, torque is 16NM
Packaging
Packing Data | Model No Sningle | BOX | Pcs/CTN | N.W/PCS(kg) | G.W/CTN(kg) | Meas(mm) |
| R06-13-40W 1 | 1 | 3.3 | 4.2 | 58*26*16.5cm | |
| R06-15-60W 1 | 1 | 3.9 | 4.6 | 63*28*16.5cm | |
| R06-110-100W 1 | 1 | 5.4 | 6.5 | 67*31*16cm | |
| R06-115-200W 1 | 1 | 7.8 | 8.9 | 82*34*16cm |